{"id":975,"date":"2021-01-31T12:44:00","date_gmt":"2021-01-31T16:44:00","guid":{"rendered":"https:\/\/www.resensys.com\/Blog\/?p=975"},"modified":"2025-04-09T08:58:35","modified_gmt":"2025-04-09T12:58:35","slug":"senspot-for-monitoring-timber-bridges","status":"publish","type":"post","link":"https:\/\/www.resensys.com\/Blog\/senspot-for-monitoring-timber-bridges\/","title":{"rendered":"SenSpot\u2122 for Monitoring Timber Bridges"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Wireless SenSpot\u2122 can be used for monitoring Timber Bridge Structures:<\/h2>\n\n\n\n<p><strong>\u2022Measuring strain\/stress in timber by Wireless Strain Gauge SenSpot\u2122<\/strong><\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1385.jpg\" alt=\"Wireless Strain Gauge for measuring and monitoring strain and stress in Timber Bridge structure\" class=\"wp-image-993\"\/><figcaption><em>Wireless Strain Gauge for measuring and monitoring strain and stress in Timber Bridge structure<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<p><strong> <\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>\u2022Measuring vertical displacement and deformation under loads by Wireless Displacement SenSpot\u2122<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/01\/IMG_1424.jpg\" alt=\"Wireless Displacement Sensor for measuring and monitoring vertical displacement and deformation under loads in Timber Bridge structure\" class=\"wp-image-984\"\/><figcaption><em>Wireless Displacement Sensor for measuring vertical displacement and deformation under loads in Timber Bridge structure<\/em><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>\u2022Obtaining load rating for timber bridges by calculating load carrying capacity and using the responses of timber members in conducted load tests<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/01\/IMG_1452.jpg\" alt=\"Obtaining load rating for timber bridges by calculating load carrying capacity and using the responses of timber members in conducted load tests by wireless sensor and gauge strain displacement\" class=\"wp-image-986\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/01\/IMG_14271.jpg\" alt=\"Obtaining load rating for timber bridges by calculating load carrying capacity and using the responses of timber members in conducted load tests by wireless sensor and gauge\" class=\"wp-image-985\" width=\"580\" height=\"435\"\/><\/figure>\n\n\n\n<p><br><\/p>\n\n\n\n<p> <strong>\u2022Evaluating effectiveness of retrofit strategy; after fixing splits (cracks) in structural timber members<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/01\/IMG_1791.jpg\" alt=\"Evaluating effectiveness of retrofit strategy; after fixing splits (cracks) in structural timber members by wireless sensor and gauge strain displacement \" class=\"wp-image-987\"\/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Wireless SenSpot\u2122 can be used for monitoring Timber Bridge Structures: \u2022Measuring strain\/stress in timber by Wireless Strain Gauge SenSpot\u2122 \u2022Measuring vertical displacement and deformation under loads by Wireless Displacement SenSpot\u2122 \u2022Obtaining load rating for timber bridges by calculating load carrying capacity and using the responses of timber members in conducted load tests \u2022Evaluating effectiveness of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":978,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[8,25,7,1],"tags":[],"class_list":["post-975","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bridge-structural-health-monitoring","category-senimax","category-senspot","category-applications","cat-8-id","cat-25-id","cat-7-id","cat-1-id","has_thumb"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SenSpot\u2122 for Monitoring Timber Bridges - Resensys blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SenSpot\u2122 for Monitoring Timber Bridges - Resensys blog\" \/>\n<meta property=\"og:description\" content=\"Wireless SenSpot\u2122 can be used for monitoring Timber Bridge Structures: \u2022Measuring strain\/stress in timber by Wireless Strain Gauge SenSpot\u2122 \u2022Measuring vertical displacement and deformation under loads by Wireless Displacement SenSpot\u2122 \u2022Obtaining load rating for timber bridges by calculating load carrying capacity and using the responses of timber members in conducted load tests \u2022Evaluating effectiveness of [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/\" \/>\n<meta property=\"og:site_name\" content=\"Resensys blog\" \/>\n<meta property=\"article:published_time\" content=\"2021-01-31T16:44:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-09T12:58:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1802.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1\" \/>\n\t<meta property=\"og:image:height\" content=\"1\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Matt\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Matt\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/senspot-for-monitoring-timber-bridges\\\/\"},\"author\":{\"name\":\"Matt\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#\\\/schema\\\/person\\\/6f672cd8a6da0c15cfd791269d48cd40\"},\"headline\":\"SenSpot\u2122 for Monitoring Timber Bridges\",\"datePublished\":\"2021-01-31T16:44:00+00:00\",\"dateModified\":\"2025-04-09T12:58:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/senspot-for-monitoring-timber-bridges\\\/\"},\"wordCount\":100,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/IMG_1802.jpg\",\"articleSection\":[\"Bridge structural health monitoring\",\"SeniMax\u2122\",\"SenSpot\u2122\",\"Solutions &amp; Applications\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/senspot-for-monitoring-timber-bridges\\\/\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/\",\"name\":\"SenSpot\u2122 for Monitoring Timber Bridges - Resensys blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/IMG_1802.jpg\",\"datePublished\":\"2021-01-31T16:44:00+00:00\",\"dateModified\":\"2025-04-09T12:58:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#\\\/schema\\\/person\\\/6f672cd8a6da0c15cfd791269d48cd40\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/IMG_1802.jpg\",\"contentUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/IMG_1802.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/senspot-for-monitoring-timber-bridges\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SenSpot\u2122 for Monitoring Timber Bridges\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#website\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/\",\"name\":\"Resensys blog\",\"description\":\"News and updates about Resensys LLC\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#\\\/schema\\\/person\\\/6f672cd8a6da0c15cfd791269d48cd40\",\"name\":\"Matt\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5598e75054197c9d1ec2d7c7cb06801f83b44bf93cba3a641997b2a8e985ae69?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5598e75054197c9d1ec2d7c7cb06801f83b44bf93cba3a641997b2a8e985ae69?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5598e75054197c9d1ec2d7c7cb06801f83b44bf93cba3a641997b2a8e985ae69?s=96&d=mm&r=g\",\"caption\":\"Matt\"},\"sameAs\":[\"http:\\\/\\\/www.resensys.com\"],\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/author\\\/mehkalangmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SenSpot\u2122 for Monitoring Timber Bridges - Resensys blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/","og_locale":"en_US","og_type":"article","og_title":"SenSpot\u2122 for Monitoring Timber Bridges - Resensys blog","og_description":"Wireless SenSpot\u2122 can be used for monitoring Timber Bridge Structures: \u2022Measuring strain\/stress in timber by Wireless Strain Gauge SenSpot\u2122 \u2022Measuring vertical displacement and deformation under loads by Wireless Displacement SenSpot\u2122 \u2022Obtaining load rating for timber bridges by calculating load carrying capacity and using the responses of timber members in conducted load tests \u2022Evaluating effectiveness of [&hellip;]","og_url":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/","og_site_name":"Resensys blog","article_published_time":"2021-01-31T16:44:00+00:00","article_modified_time":"2025-04-09T12:58:35+00:00","og_image":[{"url":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1802.jpg","width":1,"height":1,"type":"image\/jpeg"}],"author":"Matt","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Matt","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#article","isPartOf":{"@id":"https:\/\/www.resensys.com\/Blog\/senspot-for-monitoring-timber-bridges\/"},"author":{"name":"Matt","@id":"https:\/\/www.resensys.com\/Blog\/#\/schema\/person\/6f672cd8a6da0c15cfd791269d48cd40"},"headline":"SenSpot\u2122 for Monitoring Timber Bridges","datePublished":"2021-01-31T16:44:00+00:00","dateModified":"2025-04-09T12:58:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.resensys.com\/Blog\/senspot-for-monitoring-timber-bridges\/"},"wordCount":100,"commentCount":0,"image":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#primaryimage"},"thumbnailUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1802.jpg","articleSection":["Bridge structural health monitoring","SeniMax\u2122","SenSpot\u2122","Solutions &amp; Applications"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.resensys.com\/Blog\/senspot-for-monitoring-timber-bridges\/","url":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/","name":"SenSpot\u2122 for Monitoring Timber Bridges - Resensys blog","isPartOf":{"@id":"https:\/\/www.resensys.com\/Blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#primaryimage"},"image":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#primaryimage"},"thumbnailUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1802.jpg","datePublished":"2021-01-31T16:44:00+00:00","dateModified":"2025-04-09T12:58:35+00:00","author":{"@id":"https:\/\/www.resensys.com\/Blog\/#\/schema\/person\/6f672cd8a6da0c15cfd791269d48cd40"},"breadcrumb":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#primaryimage","url":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1802.jpg","contentUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2021\/02\/IMG_1802.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.resensys.com\/Blog\/project\/senspot-for-monitoring-timber-bridges\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.resensys.com\/Blog\/"},{"@type":"ListItem","position":2,"name":"SenSpot\u2122 for Monitoring Timber Bridges"}]},{"@type":"WebSite","@id":"https:\/\/www.resensys.com\/Blog\/#website","url":"https:\/\/www.resensys.com\/Blog\/","name":"Resensys blog","description":"News and updates about Resensys LLC","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.resensys.com\/Blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.resensys.com\/Blog\/#\/schema\/person\/6f672cd8a6da0c15cfd791269d48cd40","name":"Matt","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/5598e75054197c9d1ec2d7c7cb06801f83b44bf93cba3a641997b2a8e985ae69?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5598e75054197c9d1ec2d7c7cb06801f83b44bf93cba3a641997b2a8e985ae69?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5598e75054197c9d1ec2d7c7cb06801f83b44bf93cba3a641997b2a8e985ae69?s=96&d=mm&r=g","caption":"Matt"},"sameAs":["http:\/\/www.resensys.com"],"url":"https:\/\/www.resensys.com\/Blog\/author\/mehkalangmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/posts\/975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/comments?post=975"}],"version-history":[{"count":26,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/posts\/975\/revisions"}],"predecessor-version":[{"id":1017,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/posts\/975\/revisions\/1017"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/media\/978"}],"wp:attachment":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/media?parent=975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/categories?post=975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/tags?post=975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}