{"id":1479,"date":"2020-01-08T20:05:06","date_gmt":"2020-01-09T00:05:06","guid":{"rendered":"http:\/\/www.resensys.com\/Blog\/?p=560"},"modified":"2020-01-08T20:05:06","modified_gmt":"2020-01-09T00:05:06","slug":"case-study-wireless-monitoring-system-on-scour-critical-bridge","status":"publish","type":"project","link":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/","title":{"rendered":"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge"},"content":{"rendered":"<p><strong>Monitored variables and members: <\/strong>piers tilt (incline; roll and pitch), water level of the river under the bridge, camera<\/p>\n<p><strong>Bridge Structure:<\/strong>&nbsp; The two west\/east-bound bridges over river consists 7 piers and 2 abutments.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/sample-8.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-566 size-full\" src=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/sample-8.png\" alt=\"sample 8\" width=\"450\" height=\"223\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/sample-8.png 450w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/sample-8-300x148.png 300w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Continuous span girder bridge<\/p>\n<p><strong>Installed Devices: <\/strong>a Resensys structural health monitoring system that was deployed on the structure consists <a href=\"http:\/\/www.resensys.com\/senspot-tilt.html\">inclinometer 2d (tilt)<\/a> and level meter SenSpot&nbsp;sensors. <a href=\"http:\/\/www.resensys.com\/senspot-tilt.html\">Inclinometer SenSpot<\/a>&nbsp;sensors also measure temperature in real time. Also, a wireless camera was deployed on the bridge. <a href=\"http:\/\/www.resensys.com\/senimax.html\">SeniMax<\/a>&nbsp;data logger with remote communication gateway were installed to collect data from SenSpot&nbsp;gauges and send them to main server and <a href=\"http:\/\/www.resensys.com\/senscope.html\">SenScope<\/a>.<\/p>\n<p style=\"text-align: left;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-573 size-medium aligncenter\" src=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-10-14.13.46-1-300x225.jpg\" alt=\"2019-09-10 14.13.46-1\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-10-14.13.46-1-300x225.jpg 300w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-10-14.13.46-1-1024x768.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.resensys.com\/senspot-tilt.html\">Inclinometer (Tilt) SenSpot sensor<\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.45-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-569\" src=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.45-1-300x225.jpg\" alt=\"2019-09-11 10.13.45-1\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.45-1-300x225.jpg 300w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.45-1-1024x768.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Wireless ultrasonic water level sensor<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.48.38.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-570\" src=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.48.38-300x225.jpg\" alt=\"2019-09-11 10.48.38\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.48.38-300x225.jpg 300w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.48.38-1024x768.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">&nbsp; Wireless Camera<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.39-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-568\" src=\"http:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.39-1-300x225.jpg\" alt=\"2019-09-11 10.13.39-1\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.39-1-300x225.jpg 300w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/2019-09-11-10.13.39-1-1024x768.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.resensys.com\/senimax.html\">SeniMax&nbsp;Gateway<\/a><\/p>\n<p><strong>Monitoring Purposes and Methods:<\/strong><\/p>\n<ul>\n<li><a href=\"http:\/\/www.resensys.com\/senspot-tilt.html\">Inclinometer 2d (tilt)&nbsp;SenSpot<\/a>&nbsp;sensors monitor pitch and roll of the piers.<\/li>\n<li>Detect pier instability hydraulics damage and scour condition<\/li>\n<li>Obtaining dependency of pitch and roll on temperature variations by performing regression analysis.<\/li>\n<li>Calculating and implementing temperature linear regression alert levels of roll and pitch for each device (2D-Alert Levels).<\/li>\n<li>Measuring water level of the river under the bridge by Level Meter<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Monitored variables and members: piers tilt (incline; roll and pitch), water level of the river under the bridge, camera Bridge Structure:&nbsp; The two west\/east-bound bridges over river consists 7 piers and 2 abutments. &nbsp; Continuous span girder bridge Installed Devices: a Resensys structural health monitoring system that was deployed on the structure consists inclinometer 2d [&hellip;]<\/p>\n","protected":false},"featured_media":572,"parent":0,"template":"","project_category":[67,75,68,69,72,76],"class_list":["post-1479","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-bridge-structural-health-monitoring","project_category-scour-critical-bridge","project_category-senimax","project_category-senspot","project_category-wireless-tilt-sensor","project_category-wireless-water-level-sensor","has_thumb"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge - Resensys blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge - Resensys blog\" \/>\n<meta property=\"og:description\" content=\"Monitored variables and members: piers tilt (incline; roll and pitch), water level of the river under the bridge, camera Bridge Structure:&nbsp; The two west\/east-bound bridges over river consists 7 piers and 2 abutments. &nbsp; Continuous span girder bridge Installed Devices: a Resensys structural health monitoring system that was deployed on the structure consists inclinometer 2d [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/\" \/>\n<meta property=\"og:site_name\" content=\"Resensys blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/c2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"533\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/\",\"name\":\"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge - Resensys blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/c2.png\",\"datePublished\":\"2020-01-09T00:05:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/c2.png\",\"contentUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/c2.png\",\"width\":533,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/case-study-wireless-monitoring-system-on-scour-critical-bridge\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Projects\",\"item\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#website\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/\",\"name\":\"Resensys blog\",\"description\":\"News and updates about Resensys LLC\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge - Resensys blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/","og_locale":"en_US","og_type":"article","og_title":"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge - Resensys blog","og_description":"Monitored variables and members: piers tilt (incline; roll and pitch), water level of the river under the bridge, camera Bridge Structure:&nbsp; The two west\/east-bound bridges over river consists 7 piers and 2 abutments. &nbsp; Continuous span girder bridge Installed Devices: a Resensys structural health monitoring system that was deployed on the structure consists inclinometer 2d [&hellip;]","og_url":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/","og_site_name":"Resensys blog","og_image":[{"width":533,"height":400,"url":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/c2.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/","url":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/","name":"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge - Resensys blog","isPartOf":{"@id":"https:\/\/www.resensys.com\/Blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/#primaryimage"},"image":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/#primaryimage"},"thumbnailUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/c2.png","datePublished":"2020-01-09T00:05:06+00:00","breadcrumb":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/#primaryimage","url":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/c2.png","contentUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2020\/01\/c2.png","width":533,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.resensys.com\/Blog\/project\/case-study-wireless-monitoring-system-on-scour-critical-bridge\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.resensys.com\/Blog\/"},{"@type":"ListItem","position":2,"name":"Projects","item":"https:\/\/www.resensys.com\/Blog\/project\/"},{"@type":"ListItem","position":3,"name":"Scour Critical Bridge Case Study: Wireless Tilt, Wireless Water Level Sensors and Camera on Continuous Span Concrete Girder Bridge"}]},{"@type":"WebSite","@id":"https:\/\/www.resensys.com\/Blog\/#website","url":"https:\/\/www.resensys.com\/Blog\/","name":"Resensys blog","description":"News and updates about Resensys LLC","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.resensys.com\/Blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/project\/1479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/types\/project"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/media\/572"}],"wp:attachment":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/media?parent=1479"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/project_category?post=1479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}