{"id":1695,"date":"2025-07-25T07:55:14","date_gmt":"2025-07-25T11:55:14","guid":{"rendered":"https:\/\/www.resensys.com\/Blog\/?post_type=project&#038;p=1695"},"modified":"2025-07-30T09:23:54","modified_gmt":"2025-07-30T13:23:54","slug":"monitoring-movable-bridges-in-kennedy-space-center-nasa-florida","status":"publish","type":"project","link":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/","title":{"rendered":"Monitoring Movable Bridges in Kennedy Space Center (NASA), Florida"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong><strong><strong><u>Brief Description and the work performed by Resensys<\/u><\/strong><\/strong><\/strong><\/h2>\n\n\n\n<p class=\"\"><strong>Case definition: <\/strong>Movable Bridges (Bascule Bridges) at the Kennedy Space Center (NASA) in Florida were instrumented with a network of Resensys wireless strain gauge SenSpot\u2122 sensors. The sensors were installed on load bearing members to monitor stress, vibration, inclination and to detect massive loads and loading cycles.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Problems:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\">Excessive stress at girders and load bearing members<\/li>\n\n\n\n<li class=\"\">Inclination and vibration at load bearing members<\/li>\n<\/ul>\n\n\n\n<p class=\"\"><strong>How to address the problem: <\/strong>Resensys <a href=\"https:\/\/resensys.com\/r20\/wireless-products-senspot\/critical-component-condition-monitoring-instrumentation.html\">wireless monitoring systems<\/a> have been deployed in a bunch of bridges the Kennedy Space Center (NASA) in Florida and based on the monitoring needs of each bridge:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong><a href=\"https:\/\/resensys.com\/r20\/wireless-products-senspot\/metal-structural-precision-strain-stress-gauge-low-power-high-sample.html\">Wireless strain gauge<\/a>:<\/strong> monitoring responses of the girders to loading and temperature change and detecting significant loads<\/li>\n\n\n\n<li class=\"\"><strong><a href=\"https:\/\/resensys.com\/r20\/wireless-products-senspot\/structural-movement-tilt-deformation-damage-detection.html\">Wireless tilt meter<\/a>:<\/strong> monitoring inclination of structural members<\/li>\n\n\n\n<li class=\"\"><strong><a href=\"https:\/\/resensys.com\/r20\/wireless-products-senspot\/energy-efficient-sensitive-easy-install-vibration-accelerometer.html\">Wireless accelerometer<\/a><\/strong>: monitoring vibration at piers and girders<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Results:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\">Detecting over-weight loads at the bridges and provide on-call remote support and reports for permit crossings<\/li>\n\n\n\n<li class=\"\">Monitoring stress\/strain and vibration at girders and significant structural members constantly to prevent sudden potential failure<\/li>\n\n\n\n<li class=\"\">Detecting over-tilting of structural members<\/li>\n\n\n\n<li class=\"\">Provide advance warning of potential failure by detecting early signs of structural distress and by collecting steady-state data and alert systems<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-3.png\"><img loading=\"lazy\" decoding=\"async\" width=\"479\" height=\"240\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-3.png\" alt=\"\" class=\"wp-image-1696\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-3.png 479w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-3-300x150.png 300w\" sizes=\"auto, (max-width: 479px) 100vw, 479px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>OWNER<\/strong><\/td><td>Kennedy Center (NASA), Florida<\/td><\/tr><tr><td><strong>SERVICE PROVIDED<\/strong><\/td><td>Monitoring Movable Bridges (Bascule Bridges) Structures<\/td><\/tr><tr><td><strong>DURATION<\/strong><\/td><td>2022-Present<\/td><\/tr><tr><td><strong>SALIENT FEATURES<\/strong><\/td><td>Remote Monitoring System<br>Monitor stress, vibration, inclination<br>Detect massive loads and loading cycles<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-4.png\"><img loading=\"lazy\" decoding=\"async\" width=\"371\" height=\"279\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-4.png\" alt=\"Wireless Strain gauge SenSpot\u2122 sensor at a girder of Banana River Bridge, Kennedy Space Center (NASA), Orlando\" class=\"wp-image-1698\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-4.png 371w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-4-300x226.png 300w\" sizes=\"auto, (max-width: 371px) 100vw, 371px\" \/><\/a><figcaption class=\"wp-element-caption\">Wireless Strain gauge SenSpot\u2122 sensor at a girder of Banana River Bridge, Kennedy Space Center (NASA), Orlando<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png\"><img loading=\"lazy\" decoding=\"async\" width=\"313\" height=\"276\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png\" alt=\"Wireless Tilt meter SenSpot\u2122 sensor at a bridge structure, Kennedy Space Center (NASA), Orlando\" class=\"wp-image-1699\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png 313w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5-300x265.png 300w\" sizes=\"auto, (max-width: 313px) 100vw, 313px\" \/><\/a><figcaption class=\"wp-element-caption\">Wireless Tilt meter SenSpot\u2122 sensor at a bridge structure, Kennedy Space Center (NASA), Orlando<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/Wireless-structural-Health-Mnoitoring-System.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"545\" height=\"409\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/Wireless-structural-Health-Mnoitoring-System.jpg\" alt=\"Wireless structural Health Monitoring System at Haulover Canal Bridge at Kennedy Space Center (NASA), Orlando\" class=\"wp-image-1701\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/Wireless-structural-Health-Mnoitoring-System.jpg 545w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/Wireless-structural-Health-Mnoitoring-System-300x225.jpg 300w\" sizes=\"auto, (max-width: 545px) 100vw, 545px\" \/><\/a><figcaption class=\"wp-element-caption\">Wireless structural Health Monitoring System at Haulover Canal Bridge at Kennedy Space Center (NASA), Orlando<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\">Photo Gallery<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-8.png\"><img loading=\"lazy\" decoding=\"async\" width=\"388\" height=\"401\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-8.png\" alt=\"Wireless accelerometer\" class=\"wp-image-1703\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-8.png 388w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-8-290x300.png 290w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-9.png\"><img loading=\"lazy\" decoding=\"async\" width=\"518\" height=\"389\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-9.png\" alt=\"\" class=\"wp-image-1704\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-9.png 518w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-9-300x225.png 300w\" sizes=\"auto, (max-width: 518px) 100vw, 518px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-12.png\"><img loading=\"lazy\" decoding=\"async\" width=\"386\" height=\"514\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-12.png\" alt=\"\" class=\"wp-image-1707\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-12.png 386w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-12-225x300.png 225w\" sizes=\"auto, (max-width: 386px) 100vw, 386px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-13.png\"><img loading=\"lazy\" decoding=\"async\" width=\"385\" height=\"514\" src=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-13.png\" alt=\"Wireless accelerometer\" class=\"wp-image-1708\" srcset=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-13.png 385w, https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-13-225x300.png 225w\" sizes=\"auto, (max-width: 385px) 100vw, 385px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Brief Description and the work performed by Resensys Case definition: Movable Bridges (Bascule Bridges) at the Kennedy Space Center (NASA) in Florida were instrumented with a network of Resensys wireless strain gauge SenSpot\u2122 sensors. The sensors were installed on load bearing members to monitor stress, vibration, inclination and to detect massive loads and loading cycles. [&hellip;]<\/p>\n","protected":false},"featured_media":1699,"parent":0,"template":"","project_category":[67,66,71,72],"class_list":["post-1695","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-bridge-structural-health-monitoring","project_category-applications","project_category-wireless-strain-sensor","project_category-wireless-tilt-sensor","has_thumb"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Monitoring Movable Bridges at NASA with Wireless SenSpot\u2122 Sensors<\/title>\n<meta name=\"description\" content=\"Wireless sensors monitor stress, tilt &amp; vibration in movable bridges at Kennedy Space Center (NASA), ensuring safety &amp; early failure detection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Monitoring Movable Bridges at NASA with Wireless SenSpot\u2122 Sensors\" \/>\n<meta property=\"og:description\" content=\"Wireless sensors monitor stress, tilt &amp; vibration in movable bridges at Kennedy Space Center (NASA), ensuring safety &amp; early failure detection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/\" \/>\n<meta property=\"og:site_name\" content=\"Resensys blog\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-30T13:23:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png\" \/>\n\t<meta property=\"og:image:width\" content=\"313\" \/>\n\t<meta property=\"og:image:height\" content=\"276\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/\",\"name\":\"Monitoring Movable Bridges at NASA with Wireless SenSpot\u2122 Sensors\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/image-5.png\",\"datePublished\":\"2025-07-25T11:55:14+00:00\",\"dateModified\":\"2025-07-30T13:23:54+00:00\",\"description\":\"Wireless sensors monitor stress, tilt & vibration in movable bridges at Kennedy Space Center (NASA), ensuring safety & early failure detection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/image-5.png\",\"contentUrl\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/image-5.png\",\"width\":313,\"height\":276,\"caption\":\"Wireless Tilt meter SenSpot\u2122 sensor at a bridge structure, Kennedy Space Center (NASA), Orlando\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Projects\",\"item\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/project\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Monitoring Movable Bridges in Kennedy Space Center (NASA), Florida\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/#website\",\"url\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/\",\"name\":\"Resensys blog\",\"description\":\"News and updates about Resensys LLC\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.resensys.com\\\/Blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Monitoring Movable Bridges at NASA with Wireless SenSpot\u2122 Sensors","description":"Wireless sensors monitor stress, tilt & vibration in movable bridges at Kennedy Space Center (NASA), ensuring safety & early failure detection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/","og_locale":"en_US","og_type":"article","og_title":"Monitoring Movable Bridges at NASA with Wireless SenSpot\u2122 Sensors","og_description":"Wireless sensors monitor stress, tilt & vibration in movable bridges at Kennedy Space Center (NASA), ensuring safety & early failure detection.","og_url":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/","og_site_name":"Resensys blog","article_modified_time":"2025-07-30T13:23:54+00:00","og_image":[{"width":313,"height":276,"url":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/","url":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/","name":"Monitoring Movable Bridges at NASA with Wireless SenSpot\u2122 Sensors","isPartOf":{"@id":"https:\/\/www.resensys.com\/Blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/#primaryimage"},"image":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/#primaryimage"},"thumbnailUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png","datePublished":"2025-07-25T11:55:14+00:00","dateModified":"2025-07-30T13:23:54+00:00","description":"Wireless sensors monitor stress, tilt & vibration in movable bridges at Kennedy Space Center (NASA), ensuring safety & early failure detection.","breadcrumb":{"@id":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/#primaryimage","url":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png","contentUrl":"https:\/\/www.resensys.com\/Blog\/wp-content\/uploads\/2025\/07\/image-5.png","width":313,"height":276,"caption":"Wireless Tilt meter SenSpot\u2122 sensor at a bridge structure, Kennedy Space Center (NASA), Orlando"},{"@type":"BreadcrumbList","@id":"https:\/\/www.resensys.com\/Blog\/project\/monitoring-movable-bridges-in-kennedy-space-center-nasa-florida\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.resensys.com\/Blog\/"},{"@type":"ListItem","position":2,"name":"Projects","item":"https:\/\/www.resensys.com\/Blog\/project\/"},{"@type":"ListItem","position":3,"name":"Monitoring Movable Bridges in Kennedy Space Center (NASA), Florida"}]},{"@type":"WebSite","@id":"https:\/\/www.resensys.com\/Blog\/#website","url":"https:\/\/www.resensys.com\/Blog\/","name":"Resensys blog","description":"News and updates about Resensys LLC","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.resensys.com\/Blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/project\/1695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/types\/project"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/media\/1699"}],"wp:attachment":[{"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/media?parent=1695"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/www.resensys.com\/Blog\/wp-json\/wp\/v2\/project_category?post=1695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}