Bridge structural health monitoring Archive

Resensys Wireless Monitoring System Deployed on US 50, Maryland

    On Sep 16th 2015, Resensys structural health monitoring system was installed on another major bridge in Maryland over US 50.  A cluster of 8 strain and 8 tilt SenSpot sensors are monitoring the functioning of

Resensys Wireless Monitoring System Deployed on US 29, Maryland

The system installed on Aug 27th 2015, consists of 8 tilt and 8 strain SenSpot sensors and one SeniMax data logger and remote communication gateway. The main purpose of the installation is to monitor operation of the

Another project close to Hagerstown on Interstate 81 bridges

These two bridges are being monitored for possible deflections of their round piers. Any inclination will be reported with an accuracy of 0.001 degrees.  

Monitoring Licking Creek Bridge

Located close to Hagerstown, MD this bridge is local to us with less than 2 hours drive. The operation of the rocker bearings is being closely monitored. Some of them are suspected to be locked and a few

Shopping Mall Covered (Victoria)

The renovation of a structure (e.g. a shopping mall) in Victoria revealed a number of structural problems which needed quick repairs. In this project, Resensys SHM system has been employed to monitor the performance of the structural

Monitoring Tie Girder Strains of a Steel Tied Arch Bridge During Erection

Resensys SHM solution was employed by HBM Engineering Group, LLC in this project for short-term monitoring of Tie Girder Strains of a steel tied arch bridge during Erection phase. Resensys system performs live data collection at the critical locations